Certleader NS0-520 Questions are updated and all NS0-520 answers are verified by experts. Once you have completely prepared with our NS0-520 exam prep kits you will be ready for the real NS0-520 exam without a problem. We have Most up-to-date Network-Appliance NS0-520 dumps study guide. PASSED NS0-520 First attempt! Here What I Did.

Also have NS0-520 free dumps questions for you:

NEW QUESTION 1

An administrator is configuring their existing Ethernet network switches to provide ISCSI LUNs to several servers. The network switches are also used for other traffic from various hosts. In this scenario,
which statement is true?

  • A. Increase the ratio of access ports to trunk ports to 2:1
  • B. Configure the MTU size to be larger on the switch and storage than on the host.
  • C. Use multiple VLANs to isolate traffic from other network traffic
  • D. Netapp recommends using the same LIFs for NFS and ISCSI traffic

Answer: C

Explanation:
VLANs offer specific benefits, such as increased security and improved network reliability that you might want to leverage in iSCSI.
You can find more information on this link:
https://docs.netapp.com/ontap-9/topic/com.netapp.doc.dot-cm-sanconf/SAN%20configuration.pdf (page 5)

NEW QUESTION 2

You have a two node Netapp ONTAP cluster that is hosting FC LUNs for 90 SAN hosts. The hosts are experiencing occasional performance problems and receiving QFULL responses from the cluster
nodes. Which action would solve this issue?

  • A. Increase the queue depth on the target ports
  • B. Configure additional FC target ports
  • C. Increase the queue depth on the initiator ports
  • D. Configure additional FC ports on the hosts

Answer: B

Explanation:
Adding more FC initiators on host will not solve this bottle-neck situation, we can try to increase the queue depth but we need the number of hosts and the number of target ports to calculate it correctly.
We need to add more FC target ports on our storage to keep the load balanced and distributed You can find more information on this link
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanconf%2FGUID-A055B184-08

NEW QUESTION 3

A company wants to use jumbo frames in their Ethernet network. They should set the packet size to which industry conventional value?

  • A. 1200
  • B. 1500
  • C. 9000
  • D. 12000

Answer: C

NEW QUESTION 4

You create a 20 GB LUN in a newly created 100 GB FlexVol volume. You then write 5 GB of data to the LUN. You have space reservation disabled on the LUN.
In this scenario, how much space do you have left on the volume?

  • A. 95 GB
  • B. 80 GB
  • C. 75 GB
  • D. 85 GB

Answer: A

Explanation:
Reference: https://library.netapp.com/ecmdocs/ECMP1368017/html/GUID-0E0B085C-5A42-43F3-9CCD- 4FD699BA6C89.html

NEW QUESTION 5

You have a Netapp ONTAP cluster and are configuring ISCSI for some new hosts . You want to ensure that ISCSI connectivity can survive physical network failures.
In this scenario, which two features would help fulfill this requirement? (choose two)

  • A. Broadcast domains
  • B. Failover groups
  • C. MPIO
  • D. Interface groups

Answer: CD

Explanation:
Broadcast Domains are used to segment and create failover groups automatically... Broadcast Domain do not guarantee redundancy on ISCSI because failover groups are not used on ISCSI.
Graphical user interface, text, application, email Description automatically generated
NS0-520 dumps exhibit

NEW QUESTION 6

When booting your NetApp storage system for the first time the system fails to boot.
What should you do first to address this problem?

  • A. You turn off your storage system and disk shelves, and then turn on the disk shelve
  • B. You then check the quick reference card that came with the disk shelf for information about LED responses.
  • C. You re-download the boot image to the compact flash card, then reboot the system.
  • D. You look for a description of the problem on the LCD and consol
  • E. You then follow the instructions, if provided, on the LCD and console.
  • F. You verify disk shelf compatibility and check the disk shelf IDs to verify that the disk shelf 1 (for DS14 series) must be connected to your system.

Answer: C

NEW QUESTION 7

Exhibit.
NS0-520 dumps exhibit
Referring to the exhibit, what is the total amount of space that is guaranteed for the LUNs in the
/vo1/vo1_sanlunsiprod_03 volume?

  • A. 0 GB
  • B. 300 GB
  • C. 600 GB
  • D. 2600 GB

Answer: A

NEW QUESTION 8

NS0-520 dumps exhibit
Referring to the exhibit, which container gains space savings from deduplication, compression and compaction?

  • A. the aggregate
  • B. the qtree
  • C. the volume
  • D. the LUN

Answer: C

NEW QUESTION 9

NS0-520 dumps exhibit
A customer is using both FC and NVMe in a cluster. The customer needs to do some work on AFF_1. Referring to the exhibit, what will happen?

  • A. The NVMe namespaces on AFF_2 will be available after takeover of AFF_1.
  • B. The FC LUNs that use cluster interconnect to access the LUNs on AFF_1 will be unavailable after failover.
  • C. The FC LUNs on node AFF_2 will be unavailable after failover of AFF_1.
  • D. The NVMe namespaces on AFF_1 will be unavailable after takeover by AFF_2.

Answer: C

NEW QUESTION 10

A customer wants to move its iSCSI SAN data from the edge locations into the cloud for data analytics, while keeping the ability to access modify the data.
Which two combined solutions meet the customer's requirements in this scenario? (Choose two.)

  • A. Use Microsoft Azure compute resources to access the near cloud AFF SnapMirror data for analytics.
  • B. Deploy ONTAP Cloud at edge locations find use SnapVault to move the data into an AFF on-premises data center.
  • C. Deploy ONTAP Select at edge locations and use SnapMirror to move the data to AFF near cloud with the NetApp Private Storage (NPS) service.
  • D. Use Amazon Web Services (AWS) compute resources to access ONTAP Select data at the edge office locations for analytics.

Answer: AD

NEW QUESTION 11

NS0-520 dumps exhibit
You have a LUN owned by Node 01 and mapped using the default Selective LUN Map (SLM) configuration. You want to enable your host to access this LUN and facilitate future maintenance.
Which best-practice zone configuration accomplishes this task?

  • A. Zone 1: HBA 0, LIF_1, LIF_3, LIF_5 and LIF_7 Zone 2: HBA 1, LIF_2, LIF_4, LIF_6 and LIF_8
  • B. Zone 1: HBA 0, HBA 1, LIF_1, LIF_2, LIF_3, LIF_4, LIF_5, LIF_6, LIF_7, LIF_8
  • C. Zone 1: HBA 0, LIF_1, LIF_3 Zone 2: HBA 1, LIF_2, LIF_4
  • D. Zone 1: HBA 0, HBA 1, LIF_1, LIF_2, L1F_3, LIF_4

Answer: D

NEW QUESTION 12

Referring to the exhibit, which two actions would you perform to ensure that each host has valid multipathing? (choose two)
NS0-520 dumps exhibit

  • A. Verify that the VLANs are properly configured on the switches
  • B. Verify that the VLANs are properly configured on the ONTAP cluster
  • C. Verify that ALUA is enabled on the switches
  • D. Verify that ISCSI service is started on the ONTAP cluster

Answer: AB

Explanation:
Iscsi is already started, we can not run those commands successfully if the protocol is not started ALUA is enabled on hosts, It is not enabled on switches
VLANs are configured on the Netapp and switches, they need to be properly configured on both sides to work correctly
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-nmg%2FGUID-52AE6E9C-13B6

NEW QUESTION 13

A user cannot add more than one NVMe data LIF in ONTAP 9.4 on an SVM with a data protocol parameter set to nvme.
In this scenario, what is the problem?

  • A. The SVM data protocol should be set to FC.
  • B. The NVMe namespace is not created.
  • C. A demo license is used.
  • D. Only one NVMe data LIF can be configured per SVM.

Answer: B

NEW QUESTION 14

Which formula is appropriate for calculating target port Queue Depth?

  • A. The number of LIFs using a physical port * 256
  • B. The sum of the Queue Depth setting for all hosts using a physical port
  • C. The number of LIFs using the physical port * Maximum Host HBA Queue Depth setting
  • D. The number of physical ports * 2048

Answer: C

NEW QUESTION 15

Which topology allows for guaranteed maximum network performance for iSCSI?

  • A. isolated VLAN network
  • B. MetroWAN network
  • C. direct connect
  • D. WAN network

Answer: C

NEW QUESTION 16
......

Recommend!! Get the Full NS0-520 dumps in VCE and PDF From Dumps-hub.com, Welcome to Download: https://www.dumps-hub.com/NS0-520-dumps.html (New 234 Q&As Version)