Ucertify 642-035 Questions are updated and all 642-035 answers are verified by experts. Once you have completely prepared with our 642-035 exam prep kits you will be ready for the real 642-035 exam without a problem. We have Improved Cisco 642-035 dumps study guide. PASSED 642-035 First attempt! Here What I Did.
2026 New 642-035 Exam Dumps with PDF and VCE Free: https://www.surepassexam.com/642-035-exam-dumps.html
Q1. Which commands can you enter to see if a component in the Cisco UCS domain generated a core file?
A. 6100-A# scope monitoring 6100-A /monitoring # scope sysdebug 6100-A /monitoring/sysdebug # show cores
Core Files: Name Fabric ID
B. 6100-A# scope sysdebug 6100-A /sysdebug # scope monitoring 6100-A /sysdebug/monitoring # show cores
Core Files: Name Fabric ID
C. 6100-A# scope system 6100-A /system # scope monitoring 6100-A /system/monitoring # show cores
Core Files: Name Fabric ID
D. 6100-A# scope cores 6100-A /cores # show cores
Core Files: Name Fabric ID
E. 6100-A# scope logging 6100-A /logging # scope monitoring 6100-A /logging/monitoring # show cores
Core Files: Name Fabric ID
Answer: A
Q2. A customer calls in a trouble ticket complaining of unacceptable read I/O latency on a Cisco UCS C210 M2 server with an LSI MegaRAID 9260-8i with an 8-disk RAID-10 virtual disk. As you validate the RAID controller configuration, which of these configured items impacts read performance at the controller level?
A. all disks are 146GB 6 Gb SAS 15K RPM SFF
B. read ahead cache is enabled
C. BGI rate = 0
D. strip size = 256k
E. no hot spare
Answer: D
Q3. For a KVM session to be successful, which two of these need to be done? (Choose two.)
A. The Cisco IMC IP address needs to be assigned on the Admin tab.
B. The Cisco IMC IP address needs to be in the same subnet as the management IP.
C. The Cisco IMC needs to be upgraded to the same version as the UCS Manager.
D. The server needs to be fully discovered.
Answer: AD
Q4. A customer is troubleshooting degraded DIMM errors on a Cisco UCS blade server and would like to reset the BMC. What is the correct command sequence to reset the BMC?
A. UCS1-A# server x/y UCS1-A /chassis/server # scope bmc UCS1-A /chassis/server/bmc # reset UCS1-A /chassis/server/bmc* # commit-buffer
B. UCS1-A# server scope UCS1-A /chassis/server # scope bmc UCS1-A /chassis/server/bmc # reset UCS1-A /chassis/server/bmc* # commit-buffer
C. UCS1-A# scope server x/y UCS1-A /chassis/server # scope bmc UCS1-A /chassis/server/bmc # reset UCS1-A /chassis/server/bmc* # commit-buffer
D. UCS1-A# scope server x/y UCS1-A /chassis/server # scope bmc UCS1-A /chassis/server/bmc* # commit-buffer
Answer: C
Q5. Which CLI command identifies the service profile that is associated with a particular compute blade, VIF, vNIC type, link state, and pinned interface?
A. show service-profile path server 1/2
B. show service-profile circuit server 1/2
C. show server-blade circuit server 1/2
D. show server-blade path server 1/2
Answer: B
Q6. In a Cisco UCS environment, what are the three power types in a power policy? (Choose three.)
A. backup
B. grid
C. redund
D. n-plus-1
E. non-redund
F. plus-1
Answer: BDE
Q7. A customer would like to create an Ethernet traffic monitoring session on a Cisco UCS server to troubleshoot network connectivity. The customer has entered the following commands via CLI:
UCS-A# scope eth-traffic-mon UCS-A /eth-traffic-mon # scope fabric a UCS-A /eth-traffic-mon/fabric # create eth-mon-session EthMonitor33 UCS-A /eth-traffic-mon/fabric/eth-mon-session* # create dest-interface 2 12 UCS-A /eth-traffic-mon/fabric/eth-mon-session/dest-interface* # set speed 20gbps UCS-A /eth-traffic-mon/fabric/eth-mon-session/dest-interface* # commit-buffer UCS-A /eth-traffic-mon/fabric/eth-mon-session/dest-interface #
Which outcome will this command sequence produce?
A. It will create an Ethernet traffic monitoring session to copy and forward traffic to the destination port at slot 2, port 12, will set the admin speed to 20 Gb/s, and will commit the transaction.
B. It will create an Ethernet traffic monitoring session to copy and forward traffic to the destination port at slot 2, port 33, will set the admin speed to 20 Gb/s, and will commit the transaction.
C. It will create an Ethernet traffic monitoring session to copy and forward traffic to the destination port at slot 33, port 12, will set the admin speed to 20 Gb/s, and will commit the transaction.
D. It will create an Ethernet traffic monitoring session to copy and forward traffic to the destination port at slot 2, port 12, will set the admin speed to 10 Gb/s, and will commit the transaction.
Answer: A
Q8. What is the recommended procedure to update Cisco UCS C-Series rack-mount server firmware?
A. Launch the Cisco UCS Firmware Update Utility from virtual media.
B. Launch the Cisco UCS Host Update Utility from virtual media.
C. Launch the Cisco UCS Server Update Utility from virtual media.
D. Launch the Cisco UCS CIMC Update Utility from virtual media.
Answer: B
Q9. Which CLI command will indicate whether a Cisco UCS C-Series rack-mount server has any failed DIMMs?
A. ucs-c250 / # scope chassis ucs-c250 /chassis # show dimm-summary
B. ucs-c250 / # scope chassis ucs-c250 /chassis # show dimm-fault C. ucs-c250 / # scope chassis ucs-c250 /chassis # show dimm-ecc
D. ucs-c250 / # scope chassis ucs-c250 /chassis # show dimm-recovery
Answer: A
Q10. While updating firmware in a Cisco UCS environment, what will the Cisco UCS Manager do?
A. show you all versions available on Cisco.com
B. show you all versions downloaded to the Cisco UCS Manager
C. show you only versions that are supported in your environment
D. show you only versions that you selected to show
E. show you old and new versions from your download
Answer: C